SolverSettings class for simulation solver configuration
SolverSettings.RdAn R6 class representing the Solver block of a Simulation. Each
field is optional and inherits the PK-Sim solver default when absent;
the underlying raw data list stays sparse so missing fields remain
absent on export.
Active bindings
dataThe raw data of the solver settings (read-only). An empty solver is always returned as a named-empty list so the JSON serialiser writes it as
{}(an object), not[](an array). PK-Sim's snapshot mapper requires the object shape.abs_tolAbsolute solver tolerance. Writable: a single numeric value, or
NULLto clear.rel_tolRelative solver tolerance. Writable: a single numeric value, or
NULLto clear.use_jacobianWhether to use the Jacobian during integration. Writable: a single logical value, or
NULLto clear.h0Initial step size. Writable: a single numeric value, or
NULLto clear.h_minMinimum step size. Writable: a single numeric value, or
NULLto clear.h_maxMaximum step size. Writable: a single numeric value, or
NULLto clear.mx_stepMaximum number of internal solver steps. Writable: a single positive whole number (stored as an integer), or
NULLto clear.